CFP last date
15 May 2024
Reseach Article

Current Mode Controller Analysis for Enhancing Quality of Power in Distribution System

Published on November 2013 by D. N. Katole, A. M. Mendhe, C. S. Kamble
2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013)
Foundation of Computer Science USA
NCIPET - Number 3
November 2013
Authors: D. N. Katole, A. M. Mendhe, C. S. Kamble
890b05eb-79a8-43cb-9725-3bbbf9bce0c5

D. N. Katole, A. M. Mendhe, C. S. Kamble . Current Mode Controller Analysis for Enhancing Quality of Power in Distribution System. 2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013). NCIPET, 3 (November 2013), 0-0.

@article{
author = { D. N. Katole, A. M. Mendhe, C. S. Kamble },
title = { Current Mode Controller Analysis for Enhancing Quality of Power in Distribution System },
journal = { 2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013) },
issue_date = { November 2013 },
volume = { NCIPET },
number = { 3 },
month = { November },
year = { 2013 },
issn = 2249-0868,
pages = { 0-0 },
numpages = 1,
url = { /proceedings/ncipet/number3/567-1376/ },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Proceeding Article
%1 2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013)
%A D. N. Katole
%A A. M. Mendhe
%A C. S. Kamble
%T Current Mode Controller Analysis for Enhancing Quality of Power in Distribution System
%J 2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013)
%@ 2249-0868
%V NCIPET
%N 3
%P 0-0
%D 2013
%I International Journal of Applied Information Systems
Abstract

In this paper, new control strategy based on current mode control for Dynamic Voltage Restorer (DVR) is proposed to mitigate the power quality problems in the supply voltage. The simulated DVR is controlled indirectly by controlling the supply current. The reference supply currents are estimated using the sensed load terminal voltage and the DC bus voltage of DVR. The control scheme is based on synchronous reference frame theory(SRFT) for the operation of capacitor supported DVR. The contol strategy is verified through the extensive simulation studies using MATLAB with its simulink and Power Systems Block set (PSB) toolboxes to demonstrate the improved performance of DVR

References
  1. Math H. J. Bollen, Understanding Power Quality Problems- Voltage Sags And Interruptions, IEEE Press, New York, 2000.
  2. A. Ghosh and G. Ledwich, Power Quality Enhancement using Custom Power devices, Kluwer Academic Publishers, London, 2002.
  3. Math H. J. Bollen and Irene Gu, Signal Processing of Power Quality Disturbances, Wiley-IEEE Press, 2006.
  4. R. C. Dugan, M. F. McGranaghan and H. W. Beaty, Electric Power Systems Quality. 2nd Edition, New York, McGraw Hill, 2006.
  5. Antonio Moreno-Munoz, Power Quality: Mitigation Technologies in a Distributed Environment, Springer-Verlag London limited, London 2007.
  6. K. R. Padiyar, FACTS Controllers in Transmission and Distribution, New Age International, New Delhi, 2007.
  7. lEEE Recommended Practices and Recommendations for Harmonics Control in Electric Power Systems, IEEE Std. 5 19, 1992.
  8. M. Vilathgamuwa, R. Perera, S. Choi, and K. Tseng, "Control of energy optimized dynamic voltage restorer", in Proc. of IEEE IECON'99, vol. 2,1999, pp. 873–878.
  9. B. N. Singh, A. Chandra, K. Al-Haddad and B. Singh, "Performance of sliding-mode and fuzzy controllers for a static synchronous series compensator", IEE Proc. on Generation, Transmission and Distribution, vol. 146, no. 2, pp. 200 – 206, March 1999.
  10. Il-Yop Chung. , Dong-Jun Won, Sang-Young Park, Seung-Il Moon and Jong-Keun Park, "The DC link energy control method in dynamic voltage restorer system", International Journal of Electrical Power & Energy Systems, vol. 25, no. 7, pp. 525-531,Sept. 2003.
  11. A. Ghosh, A. K Jindal and A Joshi, "Design of a capacitor-supported dynamic voltage restorer (DVR) for unbalanced and distorted loads", IEEE Trans. on Power Delivery, vol. 19, no. 1, pp. 405 – 413, Jan. 2004.
  12. A. Moreno-Munoz, D Oterino, M Gonzalez, F A Olivencia and J J Gonzalez-de-la-Rosa, "Study of sag compensation with DVR", in Proc. of IEEE MELECON, Benalmadena(Malaga), Spain, May 2006, pp 990-993.
  13. Amit Kumar Jindal, Arindam Ghosh and Avinash Joshi, "Critical load bus voltage control uing DVR under system frequency variation," Electric Power Systems Research, 2007, doi:10. 1016/j. epsr. 2007. 02. 006
Index Terms

Computer Science
Information Sciences

Keywords

DVR custom power device current control PSB SRFT Power Quality.