CFP last date
15 May 2024
Reseach Article

Proposed Negative Ion Generator

by V. N. Patil, B. P. Patil, N. G. Shimpi, Ashish Jha
International Journal of Applied Information Systems
Foundation of Computer Science (FCS), NY, USA
Volume 3 - Number 8
Year of Publication: 2012
Authors: V. N. Patil, B. P. Patil, N. G. Shimpi, Ashish Jha
10.5120/ijais12-450604

V. N. Patil, B. P. Patil, N. G. Shimpi, Ashish Jha . Proposed Negative Ion Generator. International Journal of Applied Information Systems. 3, 8 ( August 2012), 44-48. DOI=10.5120/ijais12-450604

@article{ 10.5120/ijais12-450604,
author = { V. N. Patil, B. P. Patil, N. G. Shimpi, Ashish Jha },
title = { Proposed Negative Ion Generator },
journal = { International Journal of Applied Information Systems },
issue_date = { August 2012 },
volume = { 3 },
number = { 8 },
month = { August },
year = { 2012 },
issn = { 2249-0868 },
pages = { 44-48 },
numpages = {9},
url = { https://www.ijais.org/archives/volume3/number8/255-0604/ },
doi = { 10.5120/ijais12-450604 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2023-07-05T10:46:10.504786+05:30
%A V. N. Patil
%A B. P. Patil
%A N. G. Shimpi
%A Ashish Jha
%T Proposed Negative Ion Generator
%J International Journal of Applied Information Systems
%@ 2249-0868
%V 3
%N 8
%P 44-48
%D 2012
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Varied number of electrons is present in air, due to the cosmic radiation. This generates a negative electric field in the atmosphere. If this natural electric field increases, then the phenomena of the corona discharge can be seen. The study of this naturally generated corona discharge was used to make the changes in the geometry of our system. Many other systems were developed by different scientists, but they had various drawbacks like cost, effective working range and generation of pollutants e. g. ozone at ground level. This paper presents a method for weather modification by artificially generation of negative ion which is of low cost, more effective over wide range and eco-friendly.

References
  1. William A. Hoppel, R. V. Anderson &Jon C. Willet Naval research laboratory "Atmospheric Electricity in the planetary bound layer" Page No. 149, Studies in Geophysics: the earth's electrical environment, National Academy Press, Washington D. C. 1986.
  2. Devendraa Siingha, V. Gopalakrishnana,, R. P. Singhc, A. K. Kamraa, Shubha Singhc, Vimlesh Panta, R. Singhd, and A. K. Singhe "The atmospheric global electric circuit: An overview" 31st May 2006. 3-8.
  3. Dr. Stacy L. Daniels "Applications of Air Ionization for Control of VOCs and PMx" Paper #918 (Session AB-7a: Advances in, and Evaluation of, IAQ Control). February 2001. 8-11.
  4. Phillip Kauffman and Arquimedes Ruiz- Columbié "Artificial Atmospheric Ionization: A Potential Window for Weather Modification", American meteorology society. 11 Jan 2005. http://www. resonantfractals. org/Magnetism/APGR.
  5. Chih Cheng Wu, Grace W. M. Lee "Oxidation of volatile organic compounds by negative air ions" Atmospheric Environment 38 (2004) 6287–6295, 7 August 2004.
  6. U. S. environment protection agency "Ozone – good up high bad nearby" Air quality index AIRNOW (Document accessed on 21st June 20). http://www. epa. gov/oaqps001/gooduphigh.
  7. M. Quast, N. R. Lalic, "Streamer Propagation in a Point-to-Plane Geometry. "Excerpt from the Proceedings of the COMSOL Conference 2009 Milan.
  8. M. Quast, N. R. Lalic Gunytronic Gasflow Sensoric Systems GmbH, Langenharter Straße 20, 4300 St. Valentin, "Measuring and Calculation of Positive Corona Currents Using Comsol Multiphysics", Excerpt from the Proceedings of the COMSOL Conference 2009 Milan.
  9. Sugimoto, T. ; Ishii, H. ; Higashiyama, Y. "Corona Charging and Current Measurement using Phi-type Corona Electrodes", Industry Applications, IEEE Transactions on Volume: 46, 2010, 1175 – 1180.
  10. N. Mariun , D. Ismail, K. Anayet, N. Khan, M. Amran "Simulation, Design and construction of high voltage DC power supply 15 KV output using voltage multiplier circuit. " American Journal of applied sciences 3(12):2178-2183, 2006.
  11. Jean- Louis Naudin "A high voltage power supply for your lab" created on February 11, 2003 – JLN labs – Last update February 13, 2003. http://lifters. online. fr/lifters/labhvps/index. htm.
  12. Kornblueh I H, Perirsol G. M. , Speicher F. P. , "Relief from pollinosis in negatively ionized rooms", AM J. Phys. Med. 37. 18-27, 1958.
Index Terms

Computer Science
Information Sciences

Keywords

Negative ions Positive ions Ion Generator Ion counter Gerdien condenser